MODEL HR-81 FIBER DRAWING FURNACE
The Model HR-81 fiber drawing furnace is designed for operation to
2400°C with preforms up to 61 mm in diameter. The furnace features a simplified
long-life, high-purity graphite resistance element which delivers concentrated heat
through a linear graphite tube (available with a split liner for altering the hot zone
profile) that serves to protect the element and control inert gas flow. Encapsulated
graphite felt insulation surrounds the heating element. Protective inert gas flow routing
is simple and effective with top and bottom gas screens, top adjustable iris assembly and
bottom water-cooled slide door assembly. Safety interlocked top and bottom plugs permit
convenient evacuation and backfilling of the furnace prior to operation. A 30 kVA power
supply is also included, complete with a separately housed main transformer in a NEMA
enclosure and 10 feet of flexible power cables to couple the furnace to the transformer.
The Model HR-81 drawing furnace coupled with Thermal Technologys Gas Purification and Oxygen Analyzer will produce excellent element life in
excess of 1000 hours.
OPERATING GAS
The furnace MUST be operated with an inert gas
(helium, argon, or an argon/helium mixture). The gas must be dry and oxygen-free (less
than 1 PPM water and oxygen). The use of Thermal Technologys Gas Purification
System (Model IGP-1B) is recommended.
RECOMMENDED ACCESSORIES
- Vacuum Pump
- Gas Purification and Oxygen Analyzer
- Optical Pyrometer
- Temperature Controller
|